Ainuo ANRGS(F) Series Grid Simulator Runs Four-Quadrant Tests

Intepro Systems' Ainuo ANRGS(F) Series simulates sags, surges, and transients with AC, DC, and AC+DC output from 3 to 120 kVA.

Validating inverters, UPS systems, and EV power conversion equipment requires a source that can reproduce abnormal grid conditions and absorb power flowing back from the unit under test. Intepro now offers the Ainuo ANRGS(F) Series Regenerative Grid Simulator, a programmable AC/DC source that simulates real-world grid conditions while sourcing and sinking power across all four quadrants. Its regenerative operation reduces energy use and operating costs during high-power testing.

EMC Test Functions

  • Harmonics and interharmonics emissions: Harmonic synthesis from the 2nd to 50th order with a 3,000 Hz bandwidth simulates grid distortion to test equipment tolerance. Standards: IEC 61000-3-2, IEC 61000-3-12
  • Voltage dips, short interruptions, and variations: Step, pulse, and sequence programming generate voltage sags, rises, dropouts, and transients. Standards: IEC 61000-4-11 (AC), IEC 61000-4-34 (high current)
  • Voltage fluctuations and flicker: Evaluates how equipment-induced fluctuations affect power networks and how susceptible the device is to rapid line variations. Standards: IEC 61000-3-3, IEC 61000-3-11

Applications

  • Power supply testing
  • UPS and inverter testing
  • EV power conversion testing
  • Battery testing
  • IEC 61000 EMC compliance testing

Industries

  • Power electronics
  • Electric vehicles

Who It's For

  • Labs validating bidirectional or regenerative devices
  • Test setups needing AC and DC output from one unit
  • High-power testing where energy use drives costs
  • Products requiring IEC 61000 harmonics, dip, or flicker testing

Features:

  • Power ratings: 3 to 120 kVA
  • Output modes: AC, DC, and AC/DC
  • Input: 342 to 480V AC, 3Ø, 47 to 63 Hz
  • AC output: 0 to 350V AC, 1Ø/3Ø, 30 to 100 Hz
  • DC output: ±495V DC
  • Efficiency: ≥92%
  • Price: Starting at $19,805
  • Lead time: 8 to 10 weeks
  • Sine wave pulse-width modulation with FPGA digital processing
  • Simulates instantaneous voltage rise and drop, short circuit, jitter, and waveform distortion
  • Programmable waveform switch-on and switch-off angles for surge current testing
  • Programmable voltage and frequency rate of change to scan a device's input specification range
  • Built-in power parameter measurement
  • Reduced operating costs through energy-saving regenerative operation

Intepro Systems
Tustin, CA
(714) 953-2686
[email protected]
inteprosystems.com

Contributors:
This piece was created with the help of generative AI tools and edited by our content team for clarity and accuracy.