60 W power supply in 2.0”x 4.0“ footprint• Input voltage range 90 – 264 VAC (universal input) • Input frequency 47 – 63 Hz • Harmonic limits EN 61000-3-2, class A • Earth leakage current 150 µA max. @264 VAC, 63 Hz • Inrush current – 115 VAC 30 A typ. • (< 2ms, cold start at 25°C) – 230 VAC 60 A typ. • Recommended circuit breaker 5 A (characteristic C or slow blow fuse) • Temperature ranges – Operating –10°C to +70°C • Storage (non-operating) –40°C to +85°C • Power derating 2.5 %/K above +50°C • Humidity (non condensing) 0 – 95 % rel. H max. • Efficiency 80 – 88 % • Switching frequency 62 kHz typ. (pulse width modulation) • Start-up time – Vin = 115 VAC <3.5s – Vin = 230 VAC <2s • Isolation voltage – Input / Output - 4000 VAC • – Input / Field Ground - 1500 VAC • – Output / Field Ground -500 VAC