Relay;E-Mech;Gen Purp;DPDT;Cur-Rtg 10A;Ctrl-V 110/120AC;Vol-Rtg 240/30AC/DC - Allied Electronics Inc
Feb. 20, 2013
Related To: Allied Electronics & Automation
RH Series General Purpose Midget Relays10 amp switching capacity and blade terminals. UL recognized, CSA certified, CE marked. Specifications. Contact Resistance: 50 M? max. (initial value). Operate Time and Release Time: SPDT, DPDT — 20 msec. max.; 3PDT, 4DPT — 25 msec. max. Insulation Resistance: 100 M? min. (measured at 500 VDC megger).Power Consumption: SPDT (AC) — 1.1 VA (50 Hz), 1 VA (60 Hz); SPDT (DC) — 0.8 W. DPDT (AC) — 1.4 VA (50 Hz), 1.2 VA (60 Hz); DPDT (DC) — 0.9 W. 3PDT (AC) — 2 VA (50 Hz), 1.7 VA (60 Hz); 3PDT (DC) — 1.5 W. 4PDT (AC) — 2.5 VA 2 VA (60 Hz); 4PDT (DC) — 1.5 W. Operating Temperature: –30°C to +70°C.Temperature Rise: Coil — 85°C max.; Contact — 65°C max.The RH series general purpose midget relays have 100 Megohms (M") insulation resistance.Standards: UL, CSA, CE, TUV | Temperature, Operating, Maximum: 70°C | Voltage, Control: 115VAC | Brand/Series: RH Series | Voltage, Rating: 240VAC | Contact Form: DPDT | Current, Rating: 10A | Resistance, Coil: 4170Ohms | Relay Type: Electro Mechanical | Material, Contact: Silver Cadmium Oxide | Termination: Plug-In Blade | Function: General Purpose | Dimensions: 0.819 in. L x 1.07 in. W x 1.39 in. H | Current Rating: 10A | Resistance, Contact: 50 milliohms (Max.) |