The Magnalight HALP-EMG-24-2L Hazardous Area Fluorescent Light Fixture is U.S./Canada U.L. approved Class 1 Division 2 Groups A, B, C and D - UL 1598A listed, has a T4C temperatue rating and is specifically designed to handle the rigors of wet and corrosive marine environments. This fixture is equipped with an added battery backup providing 90 minutes of emergency runtime.


The HALP-EMG-24-2L hazardous area fluorescent light fixture is designed for use in wet areas and saltwater-marine environments where corrosion resistance is critical to equipment longevity and safety. This Class 1 Division 2 rated fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing and an impact resistant acrylic diffuser. Corrosion resistant stainless steel latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. This fixture is UL 844 rated and Class 1 Division II, Groups A, B, C, D approved. The HALP-EMG-24-2L also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications.

This fluorescent light works, mounts and is wired like our HALP-24-2L explosion proof fluorescent light fixtures. The main difference is that we add a battery backup unit that adds emergency light functionality to the fixture. This hazardous area emergency light will run the standard UL suggested 90 minutes after power is lost. The light recharges the battery once electrical power is restored. Standard configuration includes a single emergency ballast that will run a single lamp at 900 lumens for 90 minutes.

  save this product

Product Specs

HALP-EMG-24-2L Hazardous Area U.L. Ratings

UL Listing: United States - Canada Class 1 Division 2, Groups A, B, C, D
Dimensions: W-8.25 "   L-52 "   H-7" UL 844
Weight: 8 Lbs UL 1598A Marine Type (Salt water)
Total Watts: 32*
Voltage: Multi- 120V-60hz  220V-50hz  240V-60hz  277V-60hz
Total Lumens: F17-T8 Bulbs 2650
Lamp Life Expectancy: STD-F17-T8 Bulbs 24,000 Hours
Efficiency: STD-F17-T8 Bulbs  92 Lumens per Watt
Operating Temp Range: T4C Rated -30 C to 70 C
Battery Backup: 90 minute runtime at 900 lumens.
Color Temp: 4100K-
Mounting: Flange type stainless steel
Wiring Hub: 1/2 inch threaded
U.L Approval: U.S Certificate  Canada Certificate

Meets US Coast Guard specifications.

Reviews & Comments

Be the first to leave a review.

Leave your review
Your review will be reviewed and appear online within one to two business days.
CAPTCHA Validation
CAPTCHA
Code:

Please add your email address if you would like to be entered in the prize giveaway!

Note that your Job title will be displayed with your review. Your email will NOT be displayed.

Similar Products

Magnetic Mount Led Work Light

The Larson Electronics WAL-M-LED72-120 LED work light provides operators in demanding work environments with a powerful yet highly versatile lighting solution capable of filling a wide variety of applications with equal effectiveness. This LED work ligh...

Lamp Explosion Proof LED String Light System

Part Number PL-SL-8X4FT-LED
The EPL-SL-8X4FT-LED explosion proof LED string light from Larson Electronics takes the standard design of traditional string lights and improves it through the inclusion of LED lamps instead of standard incandescent or fluorescent bulbs. This explosion...

Solar Powered Rechargeable LED Beacon

Larson Electronics announced the addition of their new solar powered SLEDB-5-M LED beacon. Incorporating a small solar panel, rechargeable batteries and a choice of permanent and magnetic mounts, this compact beacon is ideal as a warning light or barric...

Company Information

Larson Electronics LLC

9419 E US Hwy 175
Kemp, TX 75143 US
Click for Phone
Click for email

Top Stories


Social Media Twitter Facebook Reviews Blogs RSS

Company Whitepapers

LED Lighting in the Industrial Workplace

LEDs have come a long way since their creation over 50 years ago. From simple rudimentary chips that produced very low levels of red light, to the 100+ lumen per watt advanced semi-conductors now being produced, LEDs have shown a remarkable development and...

Lighting Upgrades Improve Productivity

Illumination directly affects a workers perception of the workplace and how they feel about it both physiologically and mentally. How a worker perceives their workplace in turn has a measurable effect on workplace performance. Many studies have demonstrate...

Hazardous Locations and the Fire Triangle

No matter the size or scale of your business, if you work with or produce volatile and flammable compounds, materials, chemicals, gases or vapors, you are required by federal and local regulations to protect against the possibility of ignitions, fires and ...

Top Stories
Product Catalog
Industrial Suppliers
New Products & Reviews
Product Development
Videos
Resources