Class 1 Division 2 Emergency LED Light - 4' 2 lamp

Supplier: Larson Electronics LLC
Part Number HALP-EMG-48-2L-LED (50315)

Add This

Printer Friendly Version

Email A Friend

save this product

The Magnalight HALP-EMG-48-2L-LED Hazardous Area LED Light Fixture is U.S./Canada U.L. approved Class 1 Division 2 Groups A, B, C and D - UL 1598A listed, has a T4C temperatue rating, and is specifically designed to handle the rigors of wet and corrosive marine environments. This fixture is equipped with an added battery backup providing 90 minutes of emergency runtime.


The HALP-EMG-48-2L-LED hazardous area fluorescent light fixture is designed for use in wet areas and saltwater-marine environments where corrosion resistance is critical to equipment longevity and safety. This Class 1 Division 2 rated fixture is constructed of non-corrosive materials including a polyester housing reinforced with glass fiber, a poured in gasket for reliable sealing and an impact resistant acrylic diffuser. Corrosion resistant stainless steel latches secure the lamp cover to the housing and provide a firm lock against the poured in seal to prevent drips and water intrusion. This fixture is UL 844 rated and Class 1 Division II, Groups A, B, C, D approved. The HALP-EMG-48-2L-LED also carries a UL 1598A outdoor marine rating and meets US Coast Guard specifications.

This emergency LED light works, mounts and is wired like our HALP-48-2L-LED explosion proof LED light fixtures. The main difference is that we add a battery backup unit that adds emergency light functionality to the fixture. This hazardous area emergency light will run the standard UL suggested 90 minutes after power is lost. The light recharges the battery once electrical power is restored. Standard configuration includes a single emergency battery backup that is automatically recharged and kept in a ready state.

  save this product

Product Specs

HALP-EMG-48-2L-LED Hazardous Area U.L. Ratings
UL Listing: United States - Canada Class 1 Division 2, Groups A, B, C, D
Dimensions: W-8.25 "   L-52 "   H-7" UL 844
Weight: 8 Lbs UL 1598A Marine Type (Salt water)
Total Watts: 48 watts
Voltage: Multi- 120V-60hz  220V-50hz  240V-60hz  277V-60hz
Low Voltage Optional: 12-24VDC
Lamp Life Expectancy: 5000 Hours
Efficiency: 90 Lumens per Watt
Operating Temp Range: T4C Rated -30 C to 70 C
Battery Backup: 90 minute runtime
Color Temp: 5300K- CRI-75
Mounting: Flange type stainless steel
Wiring Hub: 1/2 inch threaded
U.L Approval: U.S Certificate  Canada Certificate

Reviews & Comments

Be the first to leave a review.

Leave your review
Your review will be reviewed and appear online within one to two business days.
CAPTCHA Validation
CAPTCHA
Code:

Please add your email address if you would like to be entered in the prize giveaway!

Note that your Job title will be displayed with your review. Your email will NOT be displayed.

Similar Products

LED High Bay Light for Hazardous Areas

In a LED landscape littered with low wattage hazardous location lights, Larson Electronics released the HAL-HB-240W-LED 240 watt LED light for Class 1 Division 2 areas.  Available with a variety of optics for optimal coverage depending on mountin...

Fluorescent Explosion Proof Emergency Light

The Larson Electronics HALP-EMG-48-2L-T5HO Class 1 Division 2 emergency fluorescent light is designed to provide operators with a failsafe lighting solution that can withstand the rigors of operation in locations where corrosion and wetness is an issue....

Magnetic Mount Led Work Light

The Larson Electronics WAL-M-LED72-120 LED work light provides operators in demanding work environments with a powerful yet highly versatile lighting solution capable of filling a wide variety of applications with equal effectiveness. This LED work ligh...

Company Information

Larson Electronics LLC

9419 E US Hwy 175
Kemp, TX 75143 US
Click for Phone
Click for email

Top Stories


Social Media Twitter Facebook Reviews Blogs RSS

Company Whitepapers

LED Lighting in the Industrial Workplace

LEDs have come a long way since their creation over 50 years ago. From simple rudimentary chips that produced very low levels of red light, to the 100+ lumen per watt advanced semi-conductors now being produced, LEDs have shown a remarkable development and...

Lighting Upgrades Improve Productivity

Illumination directly affects a workers perception of the workplace and how they feel about it both physiologically and mentally. How a worker perceives their workplace in turn has a measurable effect on workplace performance. Many studies have demonstrate...

Hazardous Locations and the Fire Triangle

No matter the size or scale of your business, if you work with or produce volatile and flammable compounds, materials, chemicals, gases or vapors, you are required by federal and local regulations to protect against the possibility of ignitions, fires and ...

Top Stories
Product Catalog
Industrial Suppliers
New Products & Reviews
Product Development
Videos
Resources